National Tsing Hua University Institutional Repository:CR switch: A load-balanced switch with contention and reservation
English  |  正體中文  |  简体中文  |  全文笔数/总笔数 : 54367/62174 (87%)
造访人次 : 14538268      在线人数 : 65
RC Version 6.0 © Powered By DSPACE, MIT. Enhanced by NTHU Library IR team.
搜寻范围 查询小技巧:
  • 您可在西文检索词汇前后加上"双引号",以获取较精准的检索结果
  • 若欲以作者姓名搜寻,建议至进阶搜寻限定作者字段,可获得较完整数据
  • 进阶搜寻
    National Tsing Hua University Institutional Repository > 研究中心 > 電腦與通訊科技研發中心 > 技術報告 >  CR switch: A load-balanced switch with contention and reservation


    jsp.display-item.identifier=請使用永久網址來引用或連結此文件: http://nthur.lib.nthu.edu.tw/dspace/handle/987654321/13085


    题名: CR switch: A load-balanced switch with contention and reservation
    作者: Yu,Chao-Lin
    Chang,Cheng-Shang
    Lee,Duan-Shin
    教師: 張正尚
    日期: 2007
    出版者: Institute of Electrical and Electronics Engineers Inc.
    關聯: INFOCOM 2007. 26th IEEE International Conference on Computer Communications. IEEE,6-12 May 2007,Page(s) 1361 - 1369
    关键词: buffer storage
    packet switching
    storage management
    摘要: © 2007 Institute of Electrical and Electronics Engineers-Load-balanced switches have received a great deal of attention recently as they are much more scalable than other existing switch architectures in the literature. However, as there exist multiple paths for flows of packets to traverse through loadbalanced switches, packets in such switches may be delivered out of order. In this paper, we propose a new switch architecture, called the CR switch, that not only delivers packets in order but also guarantees 100% throughput. The key idea, as in a multiple access channel, is to operate the CR switch in two modes: (i) the contention mode in light traffic and (ii) the reservation mode in heavy traffic. To do this, we invent a new buffer management scheme, called I-VOQ (virtual output queue with insertion). With the I-VOQ scheme, we give rigorous mathematical proofs for 100% throughput and in order packet delivery of the CR switch. By computer simulations, we also demonstrate that the average packet delay of the CR switch is considerably lower than other schemes in the literature, including the uniform frame spreading scheme [8], the padded frame scheme [6] and the mailbox switch [41. © 2007 IEEE.
    相関连結: http://www.ieee.org/portal/site
    URI: http://nthur.lib.nthu.edu.tw/handle/987654321/13085
    显示于类别:[電腦與通訊科技研發中心] 技術報告
    [通訊工程研究所] 會議論文
    [電腦與通訊科技研發中心] 會議論文
    [資訊工程學系] 會議論文

    文件中的档案:

    档案 描述 大小格式浏览次数
    2030162030005.pdf488KbAdobe PDF1000检视/开启


    在NTHUR中所有的資料項目都受到原著作權保護,僅提供學術研究及教育使用,敬請尊重著作權人之權益。若須利用於商業或營利,請先取得著作權人授權。
    若發現本網站收錄之內容有侵害著作權人權益之情事,請權利人通知本網站管理者(smluo@lib.nthu.edu.tw),管理者將立即採取移除該內容等補救措施。

    SFX Query

    與系統管理員聯絡

    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 回馈