    National Tsing Hua University Institutional Repository > 生命科學院  > 生命科學系 > 期刊論文 >  Clinical evaluation of the eBsensor hand-held blood glucose monitoring system


    Please use this identifier to cite or link to this item: http://nthur.lib.nthu.edu.tw/dspace/handle/987654321/49386


    Title: Clinical evaluation of the eBsensor hand-held blood glucose monitoring system
    Authors: Chen, Chien-Chih;Tai, Der-Yan;Ho, Ping;Lai, Yiu-Kay;Lin, Jui-Jane;Mao, Simon J. T.;Lin, Chia-Chi;Hsieh, Yu-Chen;Chiang, Hsiang-Cheng;Dai, Ken-Shwo
    教師: 黎耀基
    Date: 2007
    Publisher: Elsevier
    Relation: Clinica Chimica Acta,Elsevier,Volume 377,Issues 1-2,2 February 2007,Pages 170-173
    Keywords: diabetes
    glucose monitoring system
    Clarke error grid analysis
    glucose meter
    strip
    self-monitoring
    Abstract: Background: Home glucose monitoring system is increasingly recognized as an important tool for glycemic control. We evaluated the clinical performance of the eBsensor glucose monitoring system. Methods: Fingertip capillary blood glucose concentrations from 282 subjects were measured using eBsensor glucose monitoring system and compared against predicate devices and the Yellow Springs Instruments (YSI) 2300 blood glucose analyzer. Accuracy and precision of the eBsensor glucose monitoring system were assessed using several methods. The comparative study between the eBsensor and 2 currently marketed monitoring systems was performed. Results: The 282 eBsensor readings covered a wide range from 2.6 to 24.4 mmol/l. Deming regression and Pearson correlation analyses showed a linear relationship between the eBsensor readings and the YSI reference method (eBsensor=0.9496 YSI+0.4127 mmol/l; r=0.98). Error Grid analysis demonstrated that 100% of the eBsensor readings in clinically acceptable zones A and B. The CVs for the 6 lots of strips were within the satisfactory interval (< 6%). The comparative study showed that the eBsensor readings correlated well with the OneTouch Ultra values (r=0.97) and the Glucocard II values (r=0.97). Conclusions: eBsensor is a reliable glucose monitoring system which provides high accurate and precise glucose readings over a wide range of glucose concentrations.
    URI: http://www.elsevier.com/
    http://nthur.lib.nthu.edu.tw/dspace/handle/987654321/49386
    Appears in Collections:[生命科學系] 期刊論文

    Files in This Item:

    File Description SizeFormat
    index.html0KbHTML528View/Open


    在NTHUR中所有的資料項目都受到原著作權保護,僅提供學術研究及教育使用,敬請尊重著作權人之權益。若須利用於商業或營利,請先取得著作權人授權。
    若發現本網站收錄之內容有侵害著作權人權益之情事,請權利人通知本網站管理者(smluo@lib.nthu.edu.tw),管理者將立即採取移除該內容等補救措施。

    SFX Query

    與系統管理員聯絡

    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - Feedback