    National Tsing Hua University Institutional Repository > 電機資訊學院 > 電機工程學系 > 會議論文  >  Photoacoustic array imaging of calcifications: phantom study


    Please use this identifier to cite or link to this item: http://nthur.lib.nthu.edu.tw/dspace/handle/987654321/83950


    Title: Photoacoustic array imaging of calcifications: phantom study
    Authors: Y.-Y. Cheng;T.-C. Hsiao;W.-T. Tien;S.-B. Luo;D.-Y. Chiou;M.-L. Li
    教師: 李夢麟
    Date: 2012
    Publisher: Society of Photo-optical Instrumentation Engineers (SPIE)
    Relation: Conference on Photons Plus Ultrasound - Imaging and Sensing/Photonics West BiOS Symposium, San Francisco, CA, JAN 22-24, 2012
    Keywords: BREAST
    ULTRASOUND
    Abstract: Breast calcification is one of the most important indicators for early breast cancer detection. In this study, based on a medical ultrasound array imaging platform, we attempt to develop a real-time and high penetration photoacoustic (PA) array imaging system for visualization of breast calcifications. Phantom studies were used to verify the imaging capability and penetration depth of the developed PA array system for calcification imaging. Intralipid gelatin phantoms with different-sized hydroxyapatite (HA) particles - major chemical composition of the breast calcification associated with malignant breast cancers - embedded were imaged. Laser at 750 nm was used for photoacoustic excitation and a custom-made 5-MHz photoacoustic array transducer with linear light guides was applied for photoacoustic signal detection. Experimental results demonstrated that this system is capable of calcification imaging of 0.3-0.5 mm HA particles. For the 0.5-mm HA particles, the imaging contrast was about 34 dB and the achievable penetration was 20 mm where the axial, lateral, and elevational resolution of this PA array imaging system is 0.39 mm, 0.38 mm, and 1.25 mm, respectively. The highest frame rate was 10 frames/sec limited by the laser pulse rate. Overall, our results demonstrate that it is promising for PA imaging as a real-time diagnosis and biopsy guidance tool of breast micro-calcifications outside mass lesion. Future work will focus on optimization of the photoacoustic transducer to further improve the penetration depth and development of photoacoustic and ultrasound dual-modal imaging to enhance the calcification imaging capability.
    Relation Link: http://spie.org/
    URI: http://nthur.lib.nthu.edu.tw/dspace/handle/987654321/83950
    Appears in Collections:[電機工程學系] 會議論文
    [光電研究中心] 會議論文

    Files in This Item:

    File Description SizeFormat
    2030143030052.pdf1477KbAdobe PDF1260View/Open


    在NTHUR中所有的資料項目都受到原著作權保護,僅提供學術研究及教育使用,敬請尊重著作權人之權益。若須利用於商業或營利,請先取得著作權人授權。
    若發現本網站收錄之內容有侵害著作權人權益之情事,請權利人通知本網站管理者(smluo@lib.nthu.edu.tw),管理者將立即採取移除該內容等補救措施。

    SFX Query

    與系統管理員聯絡

    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - Feedback